Commercial Building Permit CP-2022-003830 (Issued)
Status: Issued Application Date: Jul 5, 2022
Issue Date: Dec 6, 2022
Completed Date:
Expiration Date: Aug 8, 2024
Description: Commercial - Office - New Construction
Here is a summary of your Permit information. Use the tabs above to navigate between all of the information relating to your Permit including Reviews, Inspections and Contractors. Also, check the buttons below to see what actions you can take with this Application. For more information click on the blue questions mark icons below.
Details
Type of Work: New Construction
Approved Scope of Work: **Amendment Dated 07/06/2023 for revisions to core areas to facilitate an additional service elevator, add additional storage room to Level P1, rising curtain wall details at Cuthbert Street entrance facade, removing revolving door at N 33RD ST entrance, revising restroom facilities at Level P0, added ramp to vacant retail tenant space.**
**Amendment Dated 1/3/2023 for approval of temporary shoring and support of excavation**
For the erection of the core and shell for a new, twelve (12) story detached high-rise structure (w/terraces and green roof), to be used as Groups A-3/B/S-2 at 0th/1st Floors (Lobbies, accessory storage and offices), Groups A-3/B (Terraces and Vacant Office Space) at the 2nd through 9th & 11th floors (separate use registration and/or fit-out/CO permit(s) required prior to occupancy) Group S-2 @ 10th Floor (Mechanical space only), and Group S-2 (parking garage and accessory storage) within the basement, as per plans; separate permits required for all MEP/FSP work; building to be fully sprinklered throughout in accordance with NFPA 13, with standpipes installed within the exit stairways in accordance with NFPA 14, and a fire alarm system installed in accordance with NFPA 72; emergency responder radio coverage required as per 2018 PFC Section F-510.1; providing stairway pressurization as per 2018 IBC Section 909.20.5; if field conditions vary, contact design engineer prior to the start of any work; covered walkway or sidewalk closure shall be required within seventy-six (76) feet of the building facade in accordance with Section 3306 in the 2018 IBC (separate building and/or Streets Department permit required prior to start of any work); a site safety plan shall be submitted to the building inspector prior to the start of any construction; see ZP-2022-002438 for zoning/use approval; see SR-2022-013728 for work within the public right-of-way; occupant load of entire building never to exceed 499 as per letter from Drexel University dated 10/11/2022.
Type of Structure: Office
Modular Building:
Units: 1
Number of Stories of Work: 12
High Rise Building:  
Includes Green Roof Construction:  
Facade Work Being Done:  
Includes at least 5' Excavation:
Includes Underpinning:
Impacts on Adjacent Property: No
One or both of the following applies:  
1) Construction works extends into, under, or onto a public right-of-way.
2) Project involves new, relocated, or extended driveway.
Area of Earth Disturbance (sq. ft.): 62543
New Construction Area (sq. ft.): 599500
Total Construction Area (sq. ft.): 599500
Electrical Cost of Work:
Fire Suppression Cost of Work:
Mechanical / Fuel Gas Cost of Work:
Exacation Cost of Work:
Plumbing Cost of Work:
General Construction Cost of Work: $124,400,000.00
Total Construction Cost of Work: $124,400,000.00
Design Professional: KENDALL/HEATON ASSOCIATES, INC.
Design Professional in Responsible Charge for Special Inspections (DPRC-SI):
Mark Coggin, P.E.
Locations
Address
Primary Location: 3200-22 ARCH ST, Philadelphia, PA 19104
Specific Location:
Related Information
Type Description
Building Occupancy Occupancy: A-3 Assembly (Worship, Recreation, Amusement, Other) 2259 Sq. Ft.
Building Occupancy Occupancy: A-3 Assembly (Worship, Recreation, Amusement, Other) 9431 Sq. Ft.
Building Occupancy Occupancy: B Business (Office) 1074 Sq. Ft.
Building Occupancy Occupancy: B Business (Office) 280 Sq. Ft.
Building Occupancy Occupancy: B Business (Office) 7184 Sq. Ft.
Building Occupancy Occupancy: S-2 Storage (Low Hazard) 11654 Sq. Ft.
Building Occupancy Occupancy: S-2 Storage (Low Hazard) 33848 Sq. Ft.
Building Occupancy Occupancy: S-2 Storage (Low Hazard) 42508 Sq. Ft.
Building Occupancy Occupancy: S-2 Storage (Low Hazard) 530 Sq. Ft.
Building Occupancy Occupancy: S-2 Storage (Low Hazard) 53774 Sq. Ft.
Contractor HUNTER ROBERTS HOLDINGS LLC
No Phone Number, License Number: 26101
Streets Review SR-2022-013728: Issued (Building Plan (L&I Permit Pre-Requisite))
(Tyler Updegrave)